Основные параметры
mounting type non-flush
special type hygienic design
nominal sensing distance Sn 12 mm
hysteresis 2 … 15 % of Sr
output indicator LED red
approvals/certificates Ecolab EHEDG REGULATION (EC) 1935/2004 REGULATION (EC) 2023/2006 REGULATION (EU) 1282/2011 FDA 21 CFR § 175.300 FDA 21 CFR § 177.2600 FCN 742
Электрические параметры
switching frequency
voltage supply range +Vs 10 … 30 VDC
current consumption max. (no load) 10 mA
output circuit NPN make function (NO)
voltage drop Vd
output current
output current (at cleaning temperature)
short circuit protection yes
reverse polarity protection yes
Механические параметры
type cylindrical smooth
material (sensing face) LCP
housing material stainless steel 1.4404 (V4A), LSR
dimension 17 mm
housing length 55 mm
connection types cable PVC, 2 m
Параметры окружающей среды
operating temperature -40 … +80 °C
cleaning temperature 80 … +100 °C (30 min/day)
protection class IP 68/69K & proTect+
''