Описание

Function Emergency stop module with delay up to 300s
Also suited as safety gate monitor +
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 3 s, 3 sv
Thermal current Ith max. 5 A
Cross fault detection +
Nominal voltage DC +
Connection PS
Width 45 mm
Type BH 5928
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511 Output: 3 NO or 2 NO, 1 NC instantaneous contacts and3 NO release delayed contacts Single and 2-channel operation Line fault detection on On-button,when On-button is connected to S33-S34 Manual restart with button on S33-S34 or automatic restart withbridge between S13-S14 With or without cross fault monitoring in the E-stop loop LED indication for supply, channel 1/2 and release delayed contacts Removable terminal strips Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),DIN 46 228-1/-2/-3/-4 or2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 WidthBH 5928: 45 mmBI 5928: 67.5 mm''