Описание

  • LED function display
AS-Interface inputs
D0, D1Positively driven NC contact 1
D2, D3Positively driven NC contact 2
Evaluation is performed via a safety monitor. AS-Interface outputs
D1Red LED
D2Green LED
Internal LED function display
  • The Power LED indicates the operating voltage on the bus.
  • The Fault LED indicates if a fault has been detected on the AS-Interface bus.
External LED function display
  • The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Housing material Alloy cathodically dipped
Weight
Net 0,4 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP67
Mechanical life 2 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts
According to As-i Safety at Work 1 D0,D1
1 D2,D3
Connection
1 x M12 plug connector, 4-pin
Approach speed
max. 20 m/min
Actuation frequency 1200 1/h
Retention force 10 N
Extraction force 50 N
Actuating force max.40 N
Electrical connection ratings
ASi voltage 30 V 22,5 ... 31,6 V
ASi operating current max.45 mA
ASi slave type
According to ASI specification 2.1 EA code: 7
ID code: B
ASi data in
According to ASI safety at work D0,D1,D2,D3
ASi data out
LED red D1
LED green D2
Reliability values according to EN ISO 13849-1
B10D 4,5 x 106
In combination with Actuator BETAETIGER-X-GNQMechanical values and environment
Overtravel 8 mm
In combination with Actuator BETAETIGER-X-GQMechanical values and environment
Overtravel 1 mm
''